Product Data | |
---|---|
Declared Thermal Conductivity (λ-Value) | 0.021 W/m.K at 23oC (Insulant Thickness ≥ 45 mm) |
Product Dimensions | 2400 mm x 1200 mm (2.88 m2) |
Nominal Product Thickness | 50, 80 mm |
Kooltherm K5 External Wall Board
Product Code
Description
Insulation for Use Behind Polymer Modified Renders
Kingspan Kooltherm K5 External Wall Board is a high performance, fibre-free rigid thermoset phenolic insulation core, sandwiched between two layers of tissue based facing autohesively bonded to the insulation core during manufacture.
Kingspan Kooltherm K5 External Wall Board is manufactured without the use of CFCs/HCFCs and has zero Ozone Depleting Potential (ODP) and low Global Warming Potential (GWP).
- Made in Australia
- Fibre-free core
- AS/NZS 4859.1:2018 compliant
- Product Data Table
- R-values
- Specifications
- Installation Instructions
- Downloads
- Testing and Data Table
Assumption and Key
NCC 2019 prescribes different methods to determine Total R-value Calculations for Volume 1 and Volume 2.
The R-values shown are Total R-values for the building element as required by the Energy Provisions of the National Construction Code, calculated in accordance with AS/NZS 4859.2 2018 & NZS 4214.
Kingspan Kooltherm® products are manufactured, tested and packaged in conformance with AS/NZS 4859.1:2018.
Examples shown are suitable for NCC Class 1 & 10a housing and Fire-Resisting Construction Type C walls in NCC Class 2 – 9 buildings.
For Fire-Resisting Construction Type A & B walls in NCC Class 2 – 9 buildings a Performance Solution is required.
Please contact Kingspan Insulation Technical Services on 1300 247 235 or email technical@kingspaninsulation.com.au for further guidance.
Concrete Wall (150mm)
System R-value
Product Thickness | Heat Flow In | Heat Flow Out |
---|---|---|
50 mm | RT2.6 | RT2.8 |
80 mm | RT4.0 | RT4.2 |
Masonry Block Wall (140mm)
System R-value
Product Thickness | Heat Flow In | Heat Flow Out |
---|---|---|
50 mm | RT2.7 | RT2.8 |
80 mm | RT4.1 | RT4.3 |
Steel Framed Wall
System R-value
Product Thickness | Heat Flow In | Heat Flow Out |
---|---|---|
50 mm | RT2.8 | RT2.9 |
80 mm | RT4.2 | RT4.4 |
Timber Framed Wall
System R-value
Product Thickness | Heat Flow In | Heat Flow Out |
---|---|---|
50 mm | RT2.8 | RT2.9 |
80 mm | RT4.2 | RT4.4 |
Specification Clause
The external wall insulation shall be Kingspan Kooltherm K5 External Wall Board ___ mm thick, with a tested smoke obscuration of not more than 100 m2/kg, comprising a CFC/HCFC–free and zero Ozone Depletion Potential (ODP) rigid thermoset phenolic insulation core with a tissue based facing on both sides manufactured under a management system certified to ISO 9001:2015, ISO 14001:2015, OHSAS 18001:2007 and ISO 50001:2011 by Kingspan Insulation Pty Ltd and shall be installed by approved installers (please contact Kingspan Insulation). A Project Specific Warranty provided by Kingspan Insulation must be submitted.
Specify with:
Handling & Storage
Installation should be in accordance with AS 3999:2015, Section 4 – Safety Requirements for Insulation Installation.
Storage
The polythene packaging of Kingspan Kooltherm should not be considered adequate for long term outdoor protection. Ideally, boards should be stored inside a building. If, however, outside storage cannot be avoided, then the boards should be stacked clear of the ground and covered with a polythene sheet or weatherproof tarpaulin. Boards that have been allowed to get wet should not be used.
Kingspan Kooltherm K5 External Wall Board should be protected from getting wet during periods of inclement weather prior to the application of the weatherproof render.
Installation Instructions
Kingspan Kooltherm K5 External Wall Board should only be installed by approved installers. For more information please call Technical Services on 1300 247 235 or email technical@kingspaninsulation.com.au
System installation and construction details are available from our EIFS (External Insulation & Finishing System) partners.
Downloads | |
---|---|
Download Brochure (PDF) | Download |
Pricing and Where to Buy | Download |
Request Technical Support | Download |
Project Specific Warranty | Download |
CAD PDF – Concrete Wall_Kooltherm K5 | Download |
CAD DWG – Concrete Wall_Kooltherm K5 | Download |
CAD PDF – Masonry Block Wall_Kooltherm K5 | Download |
CAD DWG – Masonry Block Wall_Kooltherm K5 | Download |
CAD PDF – Timber Framed Wall_Kooltherm K5 | Download |
CAD DWG – Timber Framed Wall_Kooltherm K5 | Download |
BIM 2016 – Kooltherm K5 Wall Board | Download |
BIM 2017 – Kooltherm K5 Wall Board | Download |
BIM 2018 – Kooltherm K5 Wall Board | Download |
BIM 2019 – Kooltherm K5 Wall Board | Download |
Testing & Data Table
Management Standards
Standard | Management System |
---|---|
ISO 9001:2015 | Quality Management |
ISO 14001:2015 | Environmental Management |
ISO 45001:2018 | Health and Safety Management |
ISO 50001:2011 | Energy Management |
Product Testing
Characteristic | Standard | Result |
---|---|---|
Compressive Stress | AS 2498.3 | Typically exceeds 120 kPa at 10% compression |
Water Vapour Resistance | BS EN 12086:1997 / I.S. EN 12086:1998 | 35 MN·s/g |
Fire Performance
Test | Test Method | Result |
---|---|---|
Ignitability Flame Spread Heat Release Smoke Release |
AS 1530.3 | Spread of Flame Index: 0 Smoke Development ≤ 3 |
Environmental Data Table
Aspect | Characteristic |
Recyclability | Non-contaminated insulation site waste is recyclable, but there are currently no facilities in Australia to process returned material |
Re-usability | Re-usable if removed with care (long term of service expected) |
Water Use | No water used in Kingspan Insulation’s manufacturing process |
Blowing Agent Global Warming Potential (GWP) | Manufactured with a blowing agent that has low GWP |
Blowing Agent Ozone Depletion Potential (ODP) | Manufactured with a CFC/HCFC-free blowing agent that has zero ODP |
Packaging | Contains 0% recycled product Polythene wrap and EPS skids 100% recyclable |